BackHomeContact Us

 

 

accw

 

Syntax

accw value

 

Function

Sets the linear acceleration of the W-axis to value .
This value is used to accelerate and decelerate the motor. The acceleration may not be modified while moving. The unit of value is in steps per
sec2 .

 

Range of Value

40,000 - 40,000,000

 

Controller Returns

None

 

Mode

Command

 

 

accx

 

Syntax

accx value

 

Function

Sets the linear acceleration of the X-axis to value .

This value is used to accelerate and decelerate the motor. The acceleration may not be modified while moving. The unit of value is in steps per sec2 .

 

Range of Value

40,000 - 40,000,000

 

Controller Returns

None

 

Mode

Command

 

accy

 

Syntax

accy value

 

Function

Sets the linear acceleration of the Y-axis to value .

This value is used to accelerate and decelerate the motor. The acceleration may not be modified while moving. The unit of value is in steps per sec2 .

 

Range of Value

40,000 - 40,000,000

 

Controller Returns

None

 

Mode

Command

 

 

accz

 

Syntax

accz value

 

Function

Sets the linear acceleration of the Z-axis to value .

This value is used to accelerate and decelerate the motor. The acceleration may not be modified while moving. The unit of value is in steps per sec2 .

 

Range of Value

40,000 - 40,000,000

 

Controller Returns

None

 

Mode

Command

 

 

 

 


 

www.OESIncorp.com

Copyright © 2002 - 2014 Optimal Engineering Systems, Inc.